The new ASPRs Standards and number of check points
The new standards provide Table 8 for the recommended number of check points required for validating product accuracies. For project areas that are larger than 2,500 square kilometers, refer to the text of the standards for guidance.
Table 8 Recommended number of check points required for validating product accuracies according to ASPRS Standards
Click for a text description of Table 8.
Horizontal Accuracy Testing of Orthoimagery and Planimetrics
Project Area (Square Kilometers) |
Total Number of Static 2D/3D Checkpoints (clearly-defined points) |
500 |
20 |
501-750 |
25 |
751-1000 |
30 |
1001-1250 |
35 |
1251-1500 |
40 |
1501-1750 |
45 |
1751-2000 |
50 |
2001-2250 |
55 |
2251-2500 |
60 |
Vertical and Horizontal Accuracy Testing of Elevation Data sets
Project Area (Square Kilometers) |
Number of Static 3D Checkpoints in NVA3 |
Number of Static 3D Checkpoints in VVA |
Total Number of Static 3D Checkpoints |
500 |
20 |
5 |
25 |
501-750 |
20 |
10 |
30 |
751-1000 |
25 |
15 |
40 |
1001-1250 |
30 |
20 |
50 |
1251-1500 |
35 |
25 |
60 |
1501-1750 |
40 |
30 |
70 |
1751-2000 |
45 |
35 |
80 |
2001-2250 |
50 |
40 |
90 |
2251-2500 |
55 |
45 |
100 |
Find more information about the new ASPRS standards here.
Download a copy of the standards here.